[HOME] [PRODUCTS] [EXPERIENCE] [COMPANY PROFILE] [CONTACTS]

HIGH POWER & EXTRA HIGH POWER TERMINATIONShigh.jpg (16722 bytes)

  • Convection cooling

  • Fan cooled option

Description

MEC Rectangular Waveguide  High Power 80-H and Extra High Power 80-E Terminations are constructed of finned aluminum waveguide containing high temperature absorbing material in intimate contact with the waveguide walls for good heat transfer. Standard units of 1,000 W or less are cooled by free air convection; for rating greater then 1,000 W, forced air must be used. For higher powers, shorter length, or lower temperature rise, an  integrally mounted fan and ducted housing may be supplied in provide forced air cooling. VSWR is 1.05 max. for operation over the full waveguide frequency band.

Designed to withstand conditions of extreme temperature and thermal shock, these terminations are ideal for use in high power systems as dummy antennas to permit testing, tuning , and maintenance without radiating RF power.

Finish is Chemical Film, per MIL-C-5541, Class 3, followed by high temperature black epoxy enamel.

A power sampling probe can be supplied as a separate unit to monitor power. Typical sampling flatness is ± 0.5dB across the entire band for levels from 30 to 50 dB.

SPECIFICATIONS

MODEL NO

FREQUENCY RANGE(GHz)

WAVEGUIDE SIZE

EQUIVALENT FLANGE

MAXIMUM POWER

LENGTH (IN. MAX.).

AVERAGE (WATTS) PEAK(KW) @ 30 PSIG DRY AIR
80-H 80-E
L80-H, L80-E 1.12-1.70 WR-650 UG-418B/U 4,000 8,000 20,000 40

LM80-H, LM80-E

1.45-2.20

WR-510

UG-1717/U 3,500 7,000 15,000 40
LA80-H, LA80-E 1.70-2.60 WR-430 UG-437B/U 3,000 6,000 10,000 30
LS80-H, LS80-E 2.20-3.30 WR-340 UG-554A/U 2,700 5,500 7,000 30
S80-H, S80-E 2.6-3.95 WR-284 UG-584/U 2,500 5,000 4,000 30
S2-80-H, S2-80-E 2.60-5.85 RG-109/U M3922/75-01 1,800 3,600 2,000 22
B80-H, B80-E 3.30-4.90 WR-229 CPR-229F 2,500 5,000 3,000 30

G80-H, G80-E

3.95-5.85

WR-187

UG-407/U 1,500 3,000 1,800 24
D80-H, D80-E 4.90-7.05 WR-159 CPR-159F 1,500 3,000 1,000 24
J80-H, J80-E 5.85-8.20

WR-137

CPR-137F

1,000 2,000 1,000 20
J80-H*, J80-E* 5.90-6.50 WR-137 CPR-137F 1,500 3,000 1,000 24
J2-80-H, J2-80-E 5.85-12.4 RG-110/U M3922/75-03 500 1,000 750 13.4
H80-H, H80-E 7.05-10.0 WR-112 UG-138/U 500 1,000 750 12
W80-H, W80-E 7.0-11.0 WR-102 M3922/70-002 500 1,000 700 12

X80-H, X80-E

8.2-12.4

WR-90

UG-135/U 500 1,000 350 12
M80-H, M80-E 10.0-15.0 WR-75 M3922/53-008 400 800 300 10.5
P80-H, P80-E 12.4-18.0 WR-62 UG-1665/U 250 500 250 9.4
N80-H, N80-E 15.0-22.0 WR-51 M3922/70-011 175 350 175 9.4
K80-H, K80-E 18.0-26.5 WR-42 UG-597/U 125 250 100 7.5
Y80-H, Y80-E 22.0-33.0 WR-34 M3922/63-010 112 224 85 7.5

A80-H, A80-E

26.5-40

WR-28

UG-599/U** 100 200 80 7.5

Notes: (1) For rating greater than 1,000 W, forced air must be used.   (2) VSWR on all  units is 1.05 max. (3) *Narrow band.  (4) ¶ Aluminum

ORDERING INFORMATION

  1. Order by model No. and specify actual frequency range, VSWR and pressurization required.
  2. Add suffix "PS" to model number for power sampling and specify level (30 to 50 dB).
  3. For integral Forced Air Cooling, contact MEC.
  4. Half-height terminations, unique mounting arrangements, other flanges and frequencies available on request.

data subject to change without notice

[Back to Terminations]  [Low Power]  [Medium Power]  [High Power]  [Liquid Cooled]  [High Power Coaxial Terminations]


1551 Osgood Street, No. Andover, MA. 01845 TEL: 978-685-2776, FAX: 978-975-4363   email:sales@microwaveeng.com